Stale Resource Cleanup¶
If the PVC is created with storage class which is having the reclaimPolicy
as Retain will not delete the PV object, backend omap metadata and backend image.
Manual deletion of PV will result in stale omap keys, values,
cephFS subvolume and rbd image.
It is required to cleanup metadata and image separately.
New CSI journal request-name mappings are stored in sharded csiDirectory
objects. For volume journals this means new entries are written to
csi.volumes.<instance_id>.<shard> where <shard> is in the range 0..10.
During upgrades, older mappings may still exist in the legacy unsharded
csi.volumes.<instance_id> object. Manual cleanup should check the shard oids
first and also clean the legacy oid when applicable.
Steps¶
1. Get PV name from PVC¶
a. get pv_name
$ kubectl get pvc mysql-pvc -owide -n prometheus
NAME STATUS VOLUME
mysql-pvc Bound pvc-bc537af8-67fc-4963-99c4-f40b3401686a
CAPACITY ACCESS MODES STORAGECLASS AGE VOLUMEMODE
20Gi RWO csi-rbd 14d Filesystem
2. Get omap key/value¶
a. get omapkey (suffix of csi.volumes.<instance_id> is value used for the CLI
option --instanceid in the provisioner
deployment). New entries are stored in one of the 11 shard oids
csi.volumes.<instance_id>.0 ... csi.volumes.<instance_id>.10, while
upgraded clusters may still have older entries in the legacy unsharded
csi.volumes.<instance_id> oid.
pv_name="pvc-bc537af8-67fc-4963-99c4-f40b3401686a"
instance_id="default"
key="csi.volume.${pv_name}"
csi_directory_oid=""
for shard in $(seq 0 10); do
oid="csi.volumes.${instance_id}.${shard}"
if rados listomapkeys "${oid}" -p pool_name 2>/dev/null | grep -Fx "${key}" >/dev/null; then
csi_directory_oid="${oid}"
break
fi
done
if [ -z "${csi_directory_oid}" ]; then
legacy_oid="csi.volumes.${instance_id}"
if rados listomapkeys "${legacy_oid}" -p pool_name 2>/dev/null | grep -Fx "${key}" >/dev/null; then
csi_directory_oid="${legacy_oid}"
fi
fi
echo "${csi_directory_oid}"
b. get omapval
$ rados getomapval "${csi_directory_oid}" "${key}" -p kube_csi
value (36 bytes) :
00000000 64 64 32 34 37 33 64 30 2d 36 61 38 63 2d 31 31 |dd2473d0-6a8c-11|
00000010 65 61 2d 39 31 31 33 2d 30 61 64 35 39 64 39 39 |ea-9113-0ad59d99|
00000020 35 63 65 37 |5ce7|
00000024
3. Delete the RBD image or CephFS subvolume¶
a. remove rbd image(csi-vol-omapval, the prefix csi-vol is value of volumeNamePrefix)
$ rbd remove csi-vol-dd2473d0-6a8c-11ea-9113-0ad59d995ce7 -p kube_csi
Removing image: 100% complete...done.
b. remove cephFS subvolume(csi-vol-omapval)
4. Delete omap object and omapkey¶
a. delete omap object
b. delete omapkey from the found oid. If the key was found in a shard oid, also try to delete it from the legacy unsharded oid to cleanup upgraded clusters.
rados rmomapkey "${csi_directory_oid}" "${key}" -p pool_name
legacy_oid="csi.volumes.${instance_id}"
if [ "${csi_directory_oid}" != "${legacy_oid}" ]; then
rados rmomapkey "${legacy_oid}" "${key}" -p pool_name || true
fi
5. Delete PV¶
a. delete pv